EZ Tuitions Logo
EZ Tuitions
Back to Blog

Mean Titre Calculations: Select Concordant Results First

5 min read• 11/24/2026• By Ananya Sharma, Academic Content Lead, EZ Tuitions• Exam Prep

Calculate titres from burette readings, select concordant results and average the right runs. Avoid rough-run, denominator and final-reading mistakes.

Laboratory flasks and measuring glassware on a chemistry bench, a subject-context photograph.
Key facts about this article
TopicExam Prep
FocusChemistry
Read time5 min
Words930
Published24 Nov 2026
Best forParents & students

A mean titre is not usually the average of every number in a titration table. First calculate the volume delivered in each run. Then apply the question's rule for selecting concordant results, leaving out the rough run where instructed.

This is a written-data lesson, not a procedure for performing a titration. All readings below are invented practice data. The task is to choose and average suitable volumes, not to select chemicals, handle apparatus or calculate a concentration.

Find each titre from two readings

Titre = final burette reading - initial burette reading. A final reading is a position on the burette scale, not automatically the volume delivered. It equals the delivered volume only when the initial reading is zero.

For example, an initial reading of 1.20 cm³ and final reading of 25.30 cm³ give a titre of 24.10 cm³. Keep a separate titre row or column so the selection is based on volumes delivered, rather than final positions.

Read the selection instruction before averaging

Concordant titres are sufficiently close to one another under the criterion being used. Use the tolerance and number of results specified in your question or course instructions. Do not assume every assessment uses an identical numerical rule.

For this exercise, the instruction is: exclude the labelled rough run; use all the accurate runs in the concordant group; the largest and smallest selected titres must differ by no more than 0.10 cm³. The boundary is inclusive because this instruction says “no more than”.

That is an explicit rule for this exercise, not a universal statement about every titration mark scheme. If your own question gives a different tolerance, apply that one instead.

Work through a full results list

  • Run Rough: initial reading 2.00 cm³; final reading 27.00 cm³; titre 25.00 cm³.
  • Run 1: initial reading 1.20 cm³; final reading 25.30 cm³; titre 24.10 cm³.
  • Run 2: initial reading 0.60 cm³; final reading 24.75 cm³; titre 24.15 cm³.
  • Run 3: initial reading 0.40 cm³; final reading 25.00 cm³; titre 24.60 cm³.
  • Run 4: initial reading 1.00 cm³; final reading 25.15 cm³; titre 24.15 cm³.

The accurate-run titres are 24.10, 24.15, 24.60 and 24.15 cm³. Runs 1, 2 and 4 form a group with range 24.15 - 24.10 = 0.05 cm³. They meet the stated 0.10 cm³ limit.

Run 3 lies outside that group. Its difference from even the largest selected titre is 24.60 - 24.15 = 0.45 cm³. Exclude it under the stated criterion. Exclude the labelled rough run as the question instructs.

Mean titre = (24.10 + 24.15 + 24.15) / 3 = 24.1333… cm³. Reported to two decimal places, that is 24.13 cm³.

Use the count of selected results

There are three selected runs, so the denominator is three. Do not divide by four because four accurate runs were recorded, or by five because five runs appear in the list.

If the instruction says to use all concordant accurate results and three meet it, do not arbitrarily select only two. Conversely, do not add a distant run merely to increase the sample size.

State your selection in the working: “Runs 1, 2 and 4 used; rough run and run 3 excluded.” That makes the arithmetic easy to check without leaving the reader to infer which values you averaged.

Avoid averaging final readings

The selected final readings are 25.30, 24.75 and 25.15 cm³. Their average is about 25.07 cm³, not the mean delivered volume of 24.13 cm³. The initial readings differ, so those final scale positions do not represent comparable delivered volumes.

As a mathematical check, the mean of the selected final readings minus the mean of their corresponding initial readings equals the mean titre. But subtracting run by run is clearer and lets you inspect concordance before calculating a mean.

Distinguish repeatability from accuracy

Closely grouped titres show that repeated results agree. That does not prove the mean is the true value. A systematic measurement or endpoint error could affect several runs in a similar way.

Do not claim that excluding a non-concordant result guarantees accuracy. Your written answer is narrower: the selected set satisfies the stated agreement criterion. Evidence of a separate procedural fault needs its own explanation.

Likewise, do not invent a reason for run 3 being high. The list shows disagreement, not its cause. Without further information, an overshot endpoint is a possible explanation rather than an established fact.

Check the units and final rounding

One cm³ equals one mL. A titre in cm³ is a volume, not a concentration in mol/dm³. Carry the unit into the final mean.

Follow the precision instruction in the question. Keep unrounded intermediate values until the final step. A mean rounded to two decimal places need not end in 0 or 5, even if individual analogue readings were recorded in 0.05 cm³ steps.

For a fresh check, two accurate titres are 18.20 and 18.30 cm³. Under an explicitly inclusive limit of 0.10 cm³, they qualify together. Their mean is 18.25 cm³.

Frequently asked questions

Is the final burette reading the titre?

Only when the initial reading is zero. Otherwise subtract initial from final.

Should I always use exactly two titres?

No. Follow the selection instruction, including whether to use all concordant accurate runs.

Does concordance prove accuracy?

No. Agreement between repeats does not rule out a shared systematic error.

Is 0.10 cm³ a universal tolerance?

No. Use the criterion specified by your question or course.

Sources

Data processing checked against BBC Bitesize titration results and analysis, the CCEA acid-base titrations factfile, and Labster's concordant-titre example. The list and selection instruction here are original practice.

Explore related tuition services: chemistry tuition · home tuition · online tuition